EasyManua.ls Logo

KOLARC MX600 - Error Resolution Table

KOLARC MX600
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
51
Error-1
It is a phase error. Occurs when any of the phases does not reach the machine.
Error-3
It is an IGBT thermal fault. It occurs when IGBTs overheat. (It is used in the SAW model.)
Error-4
Transformer thermal fault. Occurs when the transformer overheats.
Error-5
It is an IGBT thermal fault. Occurs when IGBTs overheat.
Error-6
It is a diode thermal fault. Occurs when the output diode overheats.
Error-8
The panel board data receiving error. Occurs when the panel board and the motor board
cannot communicate.
Error-9
Motor board data acquisition error. Occurs when the motor board and the control board
cannot communicate.
Error-10
It is average current error. occurs when the adjusted average
current did not draw
Error-12
It is high current error. Occurs when the machine draws high current.
Error-14
It is a high current protection fault. It usually occurs when there is an IGBT failure.
Error-20
Robot board data receiving error. occurs when the robot board cannot communicate with
the control board
Error-30
It is high current of motor error. occurs when the motor current exceeds the motor current
limit
Error-31
No signal from Motor’s encoder. Please check motor encoder cables.
Error Resolution Table
Err 01
A
A
A
A
A
A
A
A
A
A
A
A
A
V
V
V
V
V
V
V
V
V
V
V
V
V
03
04
05
06
08
09
10
12
14
20
30
31
Err
Err
Err
Err
Err
Err
Err
Err
Err
Err
Err
Err

Table of Contents