KT-70E / KT-90E / KT-70SE User Manual Page 28 of 59 24 April 2018
l Physical Do not operate near open flames (fumes!)
6.3. Placement
Place the unit on a firm surface
Place the unit horizontally. A maximum pitch of 20° from Horizontal is per-
mitted
Space required for the Compressor. Note that accessories may extend beyond
the dimensions shown below to accommodate motor configurations or op-
tional accessories.
F The compressor must not be placed directly on the wall. Minimum dis-
tance from the wall is 0.5m.
F The ambient temperature must be no higher than + 35 ° C and not lower
than + 5 ° C.
F When operated below + 10 ° C, warm-up the compressor with the con-
densate drain valves open for a few minutes.
To prevent fire hazards and to ensure adequate ventilation, place the
compressor in operation in at least 0.5m from buildings and other equip-
ment. Do not bring any flammable materials are Nourish the compres-
sor.
Superstructures or operation in crates or the like is not permitted.