KT-70E / KT-90E / KT-70SE User Manual Page 36 of 59 24 April 2018
Filter Change Interval
Capacity
Temperature
70 LPM
90 LPM
30°C
19 hours
15 hours
8.4. Extended Storage
If the compressor will not be used for an extended period:
Run the compressor for a few minutes with the fill valve open to flush out the
residual condensate. Stop the compressor, disassemble the intake filter, and add a
few drops of oil so that a light film of lubricant is aspirated and penetrates the
interior of the compressor. Stop the compressor and refit the intake filter.
Clean the external parts, eliminate any moisture, salt or oil deposits.
Store the compressor in a clean, dry location.
8.4.1. Waste Disposal
Use of the compressor generates waste that is classified as special. Wastes not classi-
fied as urban waste must be treated as special waste. Deteriorated or obsolete ma-
chines are also classified as special waste.
Waste oil must be disposed of in compliance with local ordinances.