Result
Thetransponderisreadyforuse.
Deployment
Thetransponderisdesignedforoperationinwateronly.Thetranspondermaybe
operatedinairfortestpurposesoverashortperiodoftime.
Prerequisites
Thetranspondermustbechargedbeforeuse.Itisrecommendedtotestthetransponder
withtheTestandCongurationunit(TTC)tomakesureitisworkingproperlybefore
operation.
Description
Whenyoutthetransponderontoavehicle/structure,theunitmustbepositionedwith
thetransduceruprightandtheremustbeaclearlineofsightbetweenthetransduceron
thetransponderandthevessel’stransducer.Useahoseclampwithrubberprotectionto
securethetransponder.
Internaltiltsensor
Thetransponderhasaninternaltiltsensor,whereforwardistowardstheembossed
logo,andupwardsistowardthetransducer.
Recoveringthetransponder
Itisimportanttoperformtheserecoverychecksaftereveryoperation.
Procedure
1Washtheunitthoroughlyinwarmfreshwatertodissolveanysaltdepositsand
cleanoffanysandorsilt.
2Asanextraprecaution,itisrecommendedthattheunitislefttosoakinfreshwater
toallowsalttodissolveanddiffusefromhard-to-reachareas,suchascrevices
betweenmatingparts.
Leavetheunittosoakfor24hours,oraslongaspracticalconditionsallow.
3Dryofftheunitandmakesurethatthereisnowateraroundtheon/offplugor
theexternalconnector.
4Turntheunitoffbyremovingtheon/offplugordisconnectingtheexternalcable.