Caution
EqualizethetemperatureofthecNODEMiniStobetween10°Cand40°Cbefore
chargingit.
Foron-deckcharging,usethecNODEbatterychargeronly.
Neverchargethebatteryunattended.
Procedure
1Disconnecttheon/offplugfromthecNODEtransponder.
2Lettheunitwarmuporcooldowntoanambienttemperatureof10°Cto40°C
beforecharging.
3Connectthebatterychargerplug(B)totheconnectoronthecNODEMiniSmarked
CHARGE(C).
4Connectthebatterychargertomains(110or220V AC).
5Removethepowercordaftercharging,beforeremovingtheconnectorfromthe
cNODEMiniS.
Result
TheLEDindicatoronthechargerashesgreenwhencharging.Itnormallytakesabout
30secondsbeforethechargingstartsandtheLEDindicatorstartsashinggreenafter
connectingthecNODEbatterychargertothemains.Thebatterywillbechargedwithin
1hour.TheLEDindicatorwillstaygreenwhenfullycharged.
Thetransponderisreadyforuse.