Category | Automobile Accessories |
---|---|
Charging Mode | Mode 3 |
Protection Class | IP54 |
Connector Type | Type 2 |
Installation | Wall mounting |
Communication | Modbus |
Compatibility | All EVs with Type 2 connector |
Rated Voltage | 400 V |
Provides contact details for inquiries and support from KOSTAL Solar Electric GmbH.
Explains the manual's purpose, scope, target audience, and liability.
Details limitations of manufacturer liability for device usage and modifications.
Defines the intended users (operators and electricians) and their required qualifications.
Describes correct usage, prohibited modifications, and operator responsibilities.
Explains warning symbols and information notes used throughout the manual.
Describes how to navigate through the document using clickable areas and cross-references.
Explains the meaning of various safety signs and labels on the device components.
Outlines essential safety precautions for device operation, handling, and charging cable use.
Lists the main technical features and capabilities of the ENECTOR wallbox.
Explains the meaning of all data presented on the device's type plate.
Details all items included in the product package for the ENECTOR wallbox.
Describes the physical components and construction of the ENECTOR wallbox housing.
Explains the different operating modes available for the wallbox, including Power Mode and solar modes.
Details the meaning of the LED indicators for wallbox status and operational information.
Outlines the various uses and functionalities of the wallbox, standalone or integrated.
Details the wiring for a 1-phase or 3-phase connection without a KOSTAL Smart Energy Meter.
Explains connection with KSEM for convenience functions, without a PV system.
Describes connection with KSEM and PV system for convenience functions.
Details the setup for house connection monitoring using KSEM.
Provides basic guidelines for handling the wallbox during the installation process.
Specifies requirements for choosing a suitable location for the wallbox installation.
Lists environmental conditions to avoid for safe and proper wallbox operation.
Instructions on how to safely route the AC supply cable to the wallbox.
Step-by-step guide for securely mounting the wallbox to the wall.
Details the correct procedure for making the electrical connection to the wallbox.
Guides the installation and connection of the KOSTAL Smart Energy Meter.
Instructions for installing an optional push-button for mode selection.
Explains how to connect optional shunt releases for AC shutdown.
Safety precautions to be observed when configuring the wallbox.
Explains the purpose and function of the DIP switches for wallbox configuration.
Provides examples of DIP switch settings for different application scenarios.
Details the configurable functions for DIP switch bank 1.
Details the configurable functions for DIP switch bank 2.
Instructions for closing the wallbox after configuration settings are complete.
Steps and precautions for powering on the wallbox after installation.
Outlines the two main ways to configure the wallbox with the KOSTAL Smart Energy Meter.
Guides setting up convenience functions via KSEM using an activation code.
Details setup for blackout protection monitoring via KSEM.
Explains the authorization process for charging an electric vehicle.
Step-by-step guide to start charging an electric vehicle with the wallbox.
Instructions on how to properly end the charging process and stow the cable.
General information about maintenance and its importance for safe operation.
Outlines recommended intervals for maintenance tasks like checks and tests.
Instructions on how to clean the wallbox safely and effectively from the outside.
Describes faults that may not trigger standard LED indicators, like restarts or lock mode issues.
Explains potential causes and steps for red LED flashing, user-remediable faults.
Addresses issues indicated by a solid red LED, typically requiring electrician intervention.
Interprets event messages from KSEM/Solar Portal for detailed fault diagnosis.
Step-by-step process for importing the latest firmware to the wallbox.
Information on obtaining and using original spare parts and accessories.
Key safety points the operator must be made aware of.
Operator awareness of necessary checking and servicing steps.
Explaining the meaning of the wallbox LED indicators to the operator.
Operator knowledge of the AC line circuit breaker for shutdown and restart.
Information on who to contact in the event of a fault.
Step-by-step instructions for safely dismantling the wallbox.
Guidelines for environmentally friendly disposal of electronic equipment.
User responsibility to delete personal data before decommissioning.
Specifies temperature, humidity, and duration for proper wallbox storage.
Detailed technical specifications for the ENECTOR AC 3.7/11 wallbox.
Further technical details including ambient conditions and directives.