Troubleshooting
1 12345678910111213141516
© 2022 KOSTAL Solar Electric GmbH86
IDHandling instruction for user
1
prevent-
ing char-
ging
2
aborting
charging
LED fault
32No action
3
--Off
450Check installationx-Lit up
1300No action
3
x-Off
2001Check installationxxFlashing
2005Incompatible electric vehiclexxFlashing
2008No action
3
--Off
2009Incompatible electric vehiclex-Flashing
2010Restart charging processxxFlashing
2011Restart charging process-xFlashing
2050Restart charging processx-Flashing
2051Restart charging processx-Flashing
2052Restart charging process--Flashing
2100Restart charging process, reconnect
charging cable or test another charging
cable
x-Flashing
2101Reconnect charging cable or test an-
other charging cable
--Off
2300Check AC grid connectionxxFlashing
2301Check AC grid connectionxxFlashing
2302Check AC grid connectionxxFlashing
2303Check AC grid connectionxxFlashing
2304Check AC grid connectionxxFlashing
2305Check AC grid connectionxxFlashing
2323Check configurationxxLit up
2414Restart charging processxxFlashing
2415Restart charging processxxFlashing
2416Contact service teamx-Lit up
2417Contact service teamxxLit up
2421Contact service teamxxLit up
2422Contact service teamxxLit up
2426Restart charging processxxFlashing
33072No action
3