4 Technical data
4.5 Display
4.4.3 Pulse output
Parameter Unit Value
Type NPN transistor, non-isolated
Frequency max. [Hz] 100
Voltage max. [V] 30
Current max. [mA] 300
Pulse width [ms] 0 / 5 / 100, adjustable
4.4.4 Analog output
Parameter Unit Value
Type Loop powered, set to ground (-)
Output [mA] 4...20
Power supply [VDC] 12...30
Load [Ω] 500 (at 24 V DC), max. 800
Accuracy
incl. temperature drift
[%] 0.5
Resolution [bit] 10
4.4.5 Ambient conditions
Parameter Unit Value
Storage temperature min.–max. [°C] -20...+80
Operating temperature min. - max. [°C] -20...+70
Air humidity (relative humidity, non-condensing) [%] 90
EMC interference emission/interference im-
munity
o EN 61000-6- 2
o EN 61000-6- 3
o EN61326
Protection class IP65
4.5 Display
Designation Data
Type Transflective LCD, with LED backlighting
Text display 2 lines / 7 characters (15 mm / 8 mm),
plus status information and keyword messages
Display language English
4.6 Weight
Parameter Unit Value
Weight [g] 225
4.7 Screw terminals
Parameter Unit Value
Cable cross-section max. [mm
2
] 1.5
4.8 Data storage
Parameter Value
Data storage for totals and settings At each shutdown
Operating instructions
OIE 24en-GB Edition 2022-01