24 OIO 14en Edition 07/2017 Operating Instructions
Unpacking and checking the state of delivery
Transportation, storage and disposal
Transportation , storage and d isposal
Unpacking and checking the state of delivery
1. On delivery unpack the flowmeter and check for damage during transportation.
2. Report damage during transportation immediately to the manufacturer.
3. Store the supplied pick ups and temperature sensors for the installation.
4. Dispose of packing material in accordance with the locally applicable regulations.
Lifting the flowmeter
► Fasten the hoisting equipment to the flowmeter, see Fig. 1, page 24 and lift the flowmeter.
Storage
As a result of the calibration, the internal components of the flowmeter are wetted with calibration liquid
that has a preservative effect. In addition, a special anticorrosive agent is sprayed onto the interior of the
devices before being dispatched. The connections of the flowmeter are fitted with protective caps.
Unless otherwise specified, the external components of the flowmeter are preserved with a single-coat
PU-based two-component paint. The preservation applied at the factory will protect the flowmeter for up
to six weeks, if it is stored in a dry and clean location. The manufacturer offers a long-term preservation
for storage times of up to 60 months. In the case of long-term preservation the flowmeter is additionally
packed in hermetically sealing anti-corrosion paper.
► Observe the chapters "Storage" and "Preserving".
Fig. 1 Fastening hoisting equipment – principle diagrams
WARNING
Risk of injury and/or damage to equipment should the flowmeter fall.
► Use intact and correctly dimensioned hoisting equipment in accordance with the total weight to be
transported.
► Select the attachment points for the hoisting equipment in accordance with the center of gravity
and the weight distribution.
► Use at least two load ropes.
► Do not stand under raised loads.
CAUTION
Damage to device through corrosion if stored improperly and during longer standstills.
► Protect the flowmeters against corrosion during long standstills.