Kramer Electronics Ltd.
SL-280Technical Specifications
27
Default Communication Parameters
RS-232 over Micro USB
Baud Rate:
115200
Data Bits:
8
Stop Bits:
1
Parity:
None
Command Format:
ASCII
Example (Set configuration for I/O port number 1 to digital input with the pull-up enabled):
#GPIO-CFG 1,1,0,1<CR>
Ethernet
DHCP is enabled by factory default, the following are the default addresses if no DHCP server is found.
IP Address:
192.168.1.39
Subnet Mask:
255.255.0.0
Default Gateway:
192.168.0.1
TCP Port #:
5000
Concurrent TCP Connections:
500
Full Factory Reset
Front panel buttons
Press and hold the RESET button on the rear panel for 6 seconds.
See Resetting to Factory Default Settings on page 25
.
Default Security Parameters
Default User Name: Admin
Default Password: adminpw