35
NAME-RST
Functions
Permission
Transparency
Set:
NAME-RST
Administrator
Public
Get:
-
-
-
Description
Syntax
Set:
Reset machine (DNS)
name to factory default
#NAME-RSTCR
Get:
-
-
Response
~nn@NAME-RSTSPOKCR LF
Parameters
Response Triggers
Notes
Factory default of machine (DNS) name is “SL-280-XXXXXXX, where XXXXXXX = the last 7 digits of
the serial number.
Example
Reset the DNS name of the device to the factory default:
#NAME-RST<CR>
PROT-VER
Functions
Permission
Transparency
Set:
-
-
-
Get:
PROT-VER?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device protocol
version
#PROT-VER?CR
Response
~nn@PROT-VERSP3000:versionCR LF
Parameters
versionXX.XX where X is a digit
Response Triggers
Notes
Example
#PROT-VER?<CR>