Chapter 4 Maintaining the Timeclock
4-50 ADP, Inc.
Symbology Setting (basic configuration)
Use Symbology Setting to indicate the type of bar code used on your employees’
badges, so that the timeclock can read the badges properly.
Caution
If you shut the Interleaved 12-of-5 setting off, you will not be able to read a
maintenance badge, preventing you from accessing Maintenance Mode.
Note
These settings are part of the basic configuration of the timeclock. You must
complete these settings when you power up the timeclock for the first time and if
you replace the cover assembly.
Step Display Action
1 Maintenance Mode idle
display
Press the Symbology Setting soft key.
2 Code 3-of-9
12-of-5
UPC-A
UPC-E
Code 128
EAN-8
EAN-13
Codabar
For each of the symbology settings, do one of the
following:
! Press ENTER to accept the default setting.
! Press the toggle soft keys to select OFF or ON
and press ENTER.
Note
Press ENTER on the last field to complete the
transaction.