MAINTENANCE66
ENGLISH
EVERY 4 YEARS
BReplacing Hydraulic Hose
Consult your local KUBOTA Dealer for this service.
BReplacing Fuel Lines
Consult your local KUBOTA Dealer for this service.
BReplacing Engine Breather Hose
Consult your local KUBOTA Dealer for this service.
BReplacing Radiator Hose
If you feel you are unable to make the following service
correctly and safely, contact your local KUBOTA Dealer.
See "Checking Radiator Hose and Clamp" in "EVERY 1
YEAR" in "MAINTENANCE" section.
BReplacing Mower Gear Box Oil-Seal
Consult your local KUBOTA Dealer for this service.
BReplacing Intake Air Line
If you feel you are unable to make the following service
correctly and safely, contact your local KUBOTA Dealer.
See "Checking Intake Air Line" in "EVERY 1 YEAR" in
"MAINTENANCE" section.
SERVICE AS REQUIRED
BReplacing Fuses
1. Raise the operator's seat.
2. Remove the blown fuse.
3. Place a new fuse of the same capacity in position.
A If the new fuse happens to blow out within a short time,
contact your dealer for inspection and repair. Never
"jump" the fuse with wire or foil, or install a larger
capacity fuse than is recommended.
C Protected circuit
BBleeding Fuel System
Air must be removed:
1. When the fuel filter or lines are removed.
2. When tank is completely empty.
3. After the machine has not been used for a long period
of time.
C Bleeding procedure is as follows:
1. Fill the fuel tank with fuel.
2. Start the engine and run for about 30 seconds, and
then stop the engine.
(1) Fuse location
(2) Slow blow fuse
FUSE NO.
CAPACITY
(A)
Protected circuit
(1)
20 A Engine stop
15 A Charge system
15 A Main system
15 A Aux. outlet
10 A Control system
(20 A) *(Work light)
(2)
Slow blow fuse
40 A
Check circuit against
wrong battery connection
*Option: The fuse must be in only when the work light is
attached.