EasyManua.ls Logo

KYMCO ZING 150 - Performance Test; A.C. Generator Removal

KYMCO ZING 150
182 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16. CHARGING SYSTEM
16
-
4
PERFORMANCE TEST
Perform this test with a fully charged battery.
Start and warm up the engine for 10 minutes.
Connect the battery positive cable to the
ammeter positive probe and the battery
negative cable to the ammeter negative
probe.
Then connect the voltmeter across the battery
terminals to test the charging voltage.
CHARGING PERFORMANCE:
Headlight
Switch
Position
Charging
rpm
3000 rpm
8000 rpm
OFF (Day)
2150 rpm
max.
4A 16V 6.3A 16.7V
ON (Night)
2150 rpm
max.
1.1A 14V
(1.0A min.)
2.1A 14V
(3.7A min.)
Limit Voltage Test:
Start the engine and gradually increase the
engine speed to measure the limit voltage.
Limit Voltage: 14.7±0.4V
Note: Test when the battery is fully charged.
A.C. GENERATOR
REMOVAL
Remove the A.C. generator. (Refer to 8-2.)
INSPECTION
Disconnect the A.C. generator pink and
yellow wires and measure the resistance
between the pin and yellow wires.
Resistance: 0.20.3
Do not connect the A.C. generator pink
and yellow wires to ground wire.
When testing the limit voltage, use a
tachometer for operation.
Negative Probe
Positive Probe
Negative Cable
Positive Cable
Negative Terminal
Positive Ter
minal
Pink
Yellow

Table of Contents

Related product manuals