17. Check or replace the high voltage PWB and
refit all the removed parts.
When refitting the high voltage PWB, be
careful about following points.
• Position the ground plate so that it is atop
the high voltage PWB.
• Each interface is firmly in contact with each
spring.
• The bias contact pin must be installed in
the specified position.
• The cassette pin must be inserted in the
cassette pin holder.
Figure 1-5-39
OK NG
High voltage PWB
High voltage PWB
High voltage PWB
Cassette pin
Cassette pin holder
Ground plate
Bias
contact pin
Spring
(Main charger)
Spring
(separation)
Spring
(Developing)
Spring
(Transfer)