2HA/2HB
1-5-34
(6) Detaching and refitting the fuser thermostat
Follow the procedure below to replace the fuser thermostat.
Procedure
1. Remove the fuser unit and separate the
fuser right unit and left unit (see page 1-5-
28, 30).
2. Remove the heat roller (see page 1-5-33).
3. Remove the two screws holding the fuser
thermostat and then the thermostat.
4. Replace the fuser thermostat and refit all the
removed parts.
Figure 1-5-70
(7) Detaching and refitting the fuser thermistor
Follow the procedure below to replace the fuser thermistor.
Procedure
1. Remove the fuser unit and separate the
fuser right unit and left unit (see page 1-5-
28, 30).
2. Remove the heat roller (see page 1-5-33).
3. Remove the screw holding the fuser ther-
mistor and then the thermistor.
4. Replace the fuser thermistor and refit all the
removed parts.
Figure 1-5-71
Fuser thermostat
Fuser thermistor