2JZ/2JX/2JV/2H7-1
1-3-53
U101
Setting the voltage for the primary transfer
Description
Sets the control voltage for the primary transfer.
Purpose
To change the setting when any density problems, such as too dark or light, occur.
Setting
1. Press the start key.
2. Select the item to be set.
3. Change the value using the +/- or numeric keys.
*1: 40/40, 50/40 ppm model *2: 25/25, 30/30 ppm model
4. Press the start key. The value is set.
Supplement
While this maintenance item is being executed, copying from an original is available in interrupt copying mode
(which is activated by pressing the system menu key).
Completion
Press the stop key. The screen for maintenance item No. is displayed.
Maintenance
item No.
Description
Display Description Setting range Initial setting
Normal (Full M) Primary transfer positive voltage for
magenta (full speed)
0 to 255 105
*1
/95
*2
Normal (Half M) Primary transfer positive voltage for
magenta (half speed)
0 to 255 78
*1
/75
*2
Reverse (B/W M) Primary transfer reverse voltage for
magenta in black/white mode
0 to 255 105
Add Color (C) Addition value (cyan) -127 to 127 5
Add Color (Y) Addition value (yellow) -127 to 127 5
Add Color (K) Addition value (black) -127 to 127 20
*1
/15
*2
Surround Correct Environmental correction
ON/OFF setting
0 (on)/1 (off) 0