2K3/2L3
2-3-10
YC8 1 BRSET I 0/3.3 V DC BRDSW: On/Off
Connected to
bridge
detection
switch
2 GND - - Ground
YC9 1 24VIL1 O 24 V DC 24 V DC power output to RCSW
(By way of FCSW)
Connected to
right cover
switch
2 24VIL2 I 24 V DC 24 V DC power input from RCSW
YC10 1 24VIL O 24 V DC 24 V DC poiwer output to HVPWB
Connected to
high voltage
PWB
2 24VIL O 24 V DC 24 V DC power output to HVPWB
3 MC_CLK O 0/3.3 V DC(pulse) Charging AC clock signals
4 MC_ACCNT O Analog Charging AC output control signal
5 MC_DCCNT O Analog Charging DC output control signal
6 MC_ISENS I Analog Charging output current detection signal
7 DC_REM O 0/3.3 V DC Charging DC/Transfer DC output
: On/Off
8 TRA_CNT O Analog Transfer DC output control signal
9 SEP_REM O 0/3.3 V DC Separation DC output: On/Off
10 SEP_SEL O Analog Separation DC output shift signal
11 DLP_CLK O 0/3.3 V DC(pulse) Developing AC clock signal
12 DLP_CNT O Analog Developing DC output shift signal
13 GND - - Ground
14 GND - - Ground
YC11 1 24V4 O 24 V DC 24 V DC power output to PM
Connected to
polygon
motor
2 GND - - Ground
3 POL_REM O 0/3.3 V DC PM: On/Off
4 POL_READY I 0/3.3 V DC PM ready signal
5 POL_CLK O 0/3.3 V DC(pulse) PM clock
Connector Pin Signal I/O Voltage Description