2LK/2LN/2LM/2LC-2
1-2-12
Caution
To ease setup, the device was shipped
with the developer unit already replenished
with developer. Therefore, to prevent
developer from spilling during shipping, a
developer shutter is equipped with the
developer unit.
To disengage the shutter, use the following
procedure: Note that if the shutter is not
completely disengaged and retained in
place, the developer in the developer unit
may clog at the outlet causing a damage to
the developer unit.
1. Press the fixing pin in four positions and
rotate.
*: Fully insert the fixing pin keeping the line
vertical and rotate by 90 degrees clock-
wise. Make sure that the central line is
horizontal.
Figure 1-2-16
2. Remove a screw and slide the lever
right wards.
3. Fix the lever using the screw previously
removed at the right screw hole and
unlock the developer waste exit.
*: When the device is shipped again or
removed, use the reverse procedure to
lock in the developer waste exit. Failure
to observe this caution could result in
deteriorated print quality and/or C calls.
Figure 1-2-17
Unlocking the developer waste exit
Fixing pin
Fixing pin
1
2
[Locked] [Released]
Lever
Lever
Screw
Screw
[Locked] [Released]
1
2
3