2LK/2LN/2LM/2LC
1-5-60
(5) Detaching and refitting the high voltage PWB 2
Procedure
1. Remove the main drive unit (see page 
1-5-73).
2. Pull the transfer belt unit out a little (see 
page 1-5-41).
3. Remove two connectors from the high 
voltage PWB 2 assembly.
Figure 1-5-94
4. Remove two screws.
5. Unhook two hooks and then remove the 
high voltage PWB 2.
6. Check or replace the high voltage PWB 
2 and refit all the removed parts.
Figure 1-5-95
Connectors
High voltage
PWB 2 assembly
High voltage
PWB 2 assembly
High voltage
PWB 2 assembly
Screws
Hook
Hook