2LK/2LN/2LM/2LC-2
1-3-4
Optical U089 Outputting a MIP-PG pattern -
U091 Setting the white line correction 112/112/112/75/0
U099 Adjusting original size detection DP is not installed
20/30/40/20/30/40/20/30/40
DP is installed
50/50/50/50/50/50/50/50/50
High
voltage
U100 Adjusting main high voltage
Adj AC Bias -
Set AC Auto Adj On
Set DC Bias -
Adj DC Bias 0/0/0/0/0/0/0/0/0
Set Low Temp 1
Set Charger Freq 10442/
-/
10690/
10690
8857/
-/
10690/
10690
8807/
-/
10690/
8857
11022/
10690/
10690
8857
Chk Current -
U101 Setting the voltage for the primary transfer
Normal Full 114 118 126 131
Normal Half 101 103 108 110
Normal 3/4 158
Add Color 2/2/5
Add Color 2nd -2/-3/-3/-14
Surround Correct On
U106 Setting the voltage for the secondary trans-
fer
Light/Normal 1st 125/118/
110
131/123/
115
143/134/
120
150/139/
128
Light/Normal 2nd 167/133/
112
180/140/
116
207/155/
124
220/163/
128
Light/Normal 1st 3/4(Gloss) 120/114/111 131/123/120
Light/Normal 2nd 3/4(Gloss) 155/126/111 180/140/120
Light/Normal 1st B/W - 150/144/
128/
Light/Normal 2nd B/W - 183/171/
128
Heavy1 1st 3/4 121/118/115 133/129/124
Heavy1 2nd 3/4 137/133/115 155/150/124
Section
Item
No.
Content of maintenance item
Initial setting
30ppm 35ppm 45ppm 55ppm