Specications
Specications
LS10 specications
All values given in this section are typical values.
General
Mains rating 100 V AC - 240 V AC (± 10%), 50 Hz - 60 Hz
Power consumption 10 W - 20 W max when powering another LS10
Backup power circuit 24 V DC back-up input
24 V DC output for powering another LS10
Startup time Ready to forward AVB streams in 5 seconds
Plug-and-play open standard (no license required), AVB-enabled without conguration, no manual
conguration required
Storage and operating conditions
Storage temperature -5 °C / 23 °F to 70 °C / 158 °F
Operating temperature -5 °C / 23 °F to 50 °C / 122 °F
Maximum altitude 2000 m
Climate moderate, tropical
Interface
1 LED for power status, 1 LED for fault statusIndicators
10 LEDs for link/act status
Button reset to factory settings
Ethernet port features
gPTP grandmaster capable, priority selectionManagement
RSTP: enable/disable
Port sensing Auto negotiation
Auto crossover MDI / MDIX (allows to use straight or cross cables)
Auto sensing Full or Half Duplex (Gigabit is always Full Duplex Mode)
AVB ports 10 ports at 10/100/1000 Mb/s
Connectors
8 × Ethernet etherCON I/O (5 on front, 3 on rear)Network
2 × SFP cages
Mains input IEC C13 V-Lock compatible socket
Terminal block connector 5 mm 6-point terminal block connector for GPO and DC powering with:
• 1 × 24 V DC power output (max 10 W) to power another LS10
• 1 × 24 V DC backup power input (max 10 W)
• 1 × GPO for fault indication (Relay, max 30 V DC / 1 A)
USB female micro USB type
36 LS10 owner's manual (EN) version 1.0