27 SELF-DIAGNOSIS AND FAULT IDENTIFICATION
MESSAGES
The main fault warning messages are:
no drn ”
Signals that water has not been drained from the steam
generator. If the fault appears during the de-scaling
program [dE] it will interrupt appliance functioning. Call
the technical after-sales service.
drn err ”
Drain error. Switch the machine off and back on again to
repeat the unload procedure. If the signal persists, call the
technical after-sales service.
NO bOI ”
The boiler is disabled as the drain procedure was not
performed correctly. Call the technical after-sales service.
dE End”
Appears on appliance switch-off and indicates the
requirement to indicate the steam generator de-scaling
cycle.
CAL End”
Appears on appliance switch-off and indicates the
requirement to indicate the steam generator lime scale
cleaning cycle.
Err dEt ”
Check that the container of detergent is not empty and the
detergent is withdrawn correctly. If the signal persists, call
the technical after-sales service.
Err L1” - Err L2” - Err L3”
Steam generator malfunctioning.
Switch the oven off immediately and call the technical
after-sales service.