15: Command Reference
SLC™ 8000 Advanced Console Manager User Guide 414
Display the uploaded or auto-generated IPSec conf file:
show vpn vpnconf
Description
Shows the settings for the IPsec VPN tunnel.
Temperature Commands
set temperature
Syntax
set temperature
Description
Sets the acceptable range for the internal temperature sensor (an SNMP trap is sent if the
temperature is outside of this range). Temperatures can be entered in either Celsius or
Fahrenheit; to indicate a temperature is Fahrenheit, append the degrees with an ‘F’, i.e., “75F”.
Parameter
set temperature <one or more parameters>
Parameters: low <Low Temperature in C. or F.>
high <High Temperature in C. or F.>
calibrate <Temperature Calibration in C. or F.|cancel>
Note: The calibration offset will be applied one hour after setting the value.
Description
Displays the acceptable range and the current reading from the internal temperature sensor.
show temperature
Syntax
show temperature
Description
Shows the temperature.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix SLC 8000 Series and is the answer not in the manual?

Lantronix SLC 8000 Series Specifications

General IconGeneral
BrandLantronix
ModelSLC 8000 Series
CategorySwitch
LanguageEnglish

Related product manuals