Encoder
resolution
Position error
limit
Motor
typeselection
Speed
smoothness
command, but when it comes to not, the transistor
becomes conductive. 1 means opposite to 0.
This drive provides two choices of the number of
lines of the encoder. 0 means 1000 lines, while 1
means 2500 lines.
The limit of the position following error. When the
actual position error exceeds this value, the drive
willgointoerrormodeandthefaultoutputwillbe
activated. (The actual value = the set value× 10)
This parameter is set to control the smoothness of
the speed of the motor while acceleration or
deceleration, the larger the value, the smoother the
speed in acceleration ordeceleration.
0
1 2
…
10