11 Maintenance
11.1 Maintenance Plan
BLK2FLY is a professional UAV solution and is used in varying conditions. It
needs regular maintenance to maximise the usage, life and secures the invest-
ment of the UAV solution. Find this guideline on maintenance activities that
the pilot and Leica Geosystems Service Center should perform for the system
regularly. In a summary, the intervals are:
•
Every ight check (before and after)
•
5 hours ight time check
•
50 hours ight time check
•
200 hours ight time check
Minor service performed by pilot before and after every ight.
Before ight
•
Check landing gear: Intact, no cracks, clean
•
Check propellers: Propeller edge check, ex for delamination/cracks, clean
•
Spin all propellers to check motors: Listen for noises, look for irregularities
•
Visual inspection of the BLK2FLY body and LiDAR lighthouse
•
Check the camera lenses are clean
After ight
•
Motor check: Feel for excess heat on all motors
•
Check landing gear: Intact, no cracks, clean
•
Check propellers: Propeller edge check, ex for delamination/cracks, clean
•
Visual inspection of the BLK2FLY body and LiDAR lighthouse
Minor service performed by pilot once a week or after a long day.
•
Clean any dirty surfaces: Camera lens, propellers, BLK2FLY body, landing
gear
•
Clean the LiDAR lighthouse. Be careful. Refer to General for details
•
Battery inspection for battery life/damage/pufng/charge levels
This service is recommended after 50 hours or 200 ights.
BLK2FLY
•
Visual inspection of all components: Motors, pro-
pellers, landing gear, cameras, LiDAR, Time of ight
sensor
•
If applicable, rmware updates for:
-
BLK2FLY
-
Apple iPad
-
Batteries
Apple iPad tablet
•
Functional test
•
Installation of latest rmware and applications
Acceptance test
ight
•
BLK2FLY ight performance test
General
•
Cleaning of entire BLK2FLY system
General
Every ight
5-hour check
50 hour/200 ight
check
102 Maintenance