EasyManua.ls Logo

Leister UNIPLAN 300 - UNIPLAN 500 Warning and Error Management; Understanding Error Codes and Descriptions

Leister UNIPLAN 300
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
Warning and error messages (UNIPLAN 500)
Warning and error messages are displayed as they arise in the status display (34) or in the working display
(33). If a warning message is active you may still be able to continue to work.
If an error message is active you cannot continue to work. The heating is turned o automatically, the blower
is switched on, and the drive is blocked. The corresponding error code is immediately shown in the working
display (33).
Concrete information regarding the type of error or the warning can be called up at any time using the "Warnings"
item in the "Settings" menu.
Type of
message
Display
Error code/
Warning mes-
sage
Description
Warning
Ambient
temperature
Ambient temperature is too high
Undervoltage Supply voltage is too low
Overvoltage Supply voltage is too high
Error
0001
Device has overheated
Solution: Let the device cool down
0020
Heating element is faulty
Solution: Replace the heating element
Error (contact
Leister Service
Center)
0002 Overvoltage or undervoltage of the power supply
0004 Hardware error
0008 Thermocouple is defective
0080 Automatic control unit error
0100 Blower motor error
0200 Communication module error
0400 Drive error