5
2 21 1
UNIPLAN 300 UNIPLAN 500
V~ 120 230 120 230
Hz 50 / 60
W 1800 3450 1800 3450
°C
°F
100 – 550
212 – 1022
100 – 620
212 – 1148
m/min
ft/min
1 – 16
3.3 – 52.5
mm
inch
20 / 30 / 40
0.8 / 1.2 / 1.6
rpm 8'800 12'500 12'600 18'000
L
pA
(dB) 70 (K = 3)
*
kg
lbs
15
33
16
35
a
b
c
a) mm / inch 500 / 19.7
b) mm / inch 310 / 12.2
c) mm / inch 300 / 11.8
We reserve the right to make technical changes.
Technical data
Comply with applicable, national regulations regarding the carrying or lifting of loads. For transporting the hot-air
welder use only the transport box included in the scope of delivery and carry the transport box using the handle.
The hot-air blower (9) reaches temperatures of 650°C. Therefore, take great care and allow the
hot-air blower (9) to cool down suciently before packing and transporting it (see Cool-Down
Mode). There is a risk of burns and of fire.
Never store flammable materials (such as plastic or wood) in the transport box. There is a risk of fire.
Never use the carrying handle (1) on the device or on the transport box for transporting it with a
crane.
Fold in the hot-air blower (9) prior to transport.
Use the carrying handle (1) or the handles (2)
on the aluminum housing to lift the hot-air welder
by hand.
Transporting
brushed brushless
* without auxiliary weight (15) and power cord (3)

Table of Contents