29
The machine turns on automatically after the blowers have been turned on:
• If the air temperature is more than 100°C when the device is turned on, the device switches automatically
to Cool-Down mode. The cool-down process is finished when the air temperature is less than 100°C for 2
minutes.
The machine turns o automatically:
• In Standby mode, the heating is switched o automatically after the time elapses that the user has stored (see
also Standby mode). This feature is available only on the UNIPLAN 500.
Deficient welding result quality:
• Check drive speed, welding temperature and air flow range.
• Clean the welding nozzle (9) with wire brush (see Maintenance).
• Welding nozzle (9) incorrectly adjusted (see Adjust welding nozzle).
IIf the set welding temperature has not been reached after five minutes:
• Check the supply voltage
• Reduce the air volume
Changing the weld width:
• Please contact your local distributor for further information on changing the weld width.
• Safety Instructions – Automatic Welders/Extrusion Welders/Welding Machines (Article number: 129.102)