Technical data
Voltage V~ 230
power consumption W 3000
Frequency Hz 50/60
Air flow (20°C) l/min ca. 270
Air temperature °C max. 350
Plastifizer temperature °C max. 260
Welding output (Ø 3 mm) kg/h
PE 0.6 1.3 PP 0.5 1.2 *PVC-U 0.9 1.7 (Average values at 50 Hz)
Welding output (Ø 4 mm) kg/h
PE 1.0 2.3 PP 0.9 2.0 *PVC-U 1.5 2.7 (Average values at 50 Hz)
Welding rod mm Ø 3 / Ø 4
Size L × B × Hmm450 × 98 × 260 (without welding shoe)
Weight kg 5.8 (without cable to mains)
Marking of conformity 2
Approval mark
3
Certification scheme CCA
Protection class I 1
* WELDPLAST S2-PVC
Leister Process Technologies, Galileo-Strasse 10, CH-6056 Kaegiswi/Switzerland confirms
that this
product, in the version as brought into circulation through us, fulfils the requirements
of the following EC directives. Directives:
2004/108, 2006/95.
Harmonized Standards:
EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3, EN 61000-6-2,
EN 50366, EN 60335-2-45
Kaegiswil, 06.02.2009
Bruno von Wyl Christiane Leister
Technical Director Owner
Power tools, accessories and packaging should be sorted for environmental-friendly
recycling. Only for EC countries: Do not dispose of power tools into household
waste! According to the European Directive 2002/96 on waste electrical and
electronic equipment and its incorporation into national law, power tools
that
are no longer suitable for use must be separately collected and sent for
recovery in an environmental-friendly manner.