CBX40UHV
3
OUTDOOR
SENSOR
DISCHARGE
AIR SENSOR
HEAT
1234
COOL
1234
DELAY
1234
ADJUST
NORM +
HUMIDIFICATION
SMART AUTO
EVENHEAT
1234
BLOWER
ONLY CFM
100
115
130
85
CUT FOR OPTION
Y1−Y2
2−STAGE
COMPR
R−O
HEAT
PUMP
R−DS
DEHUM
OR
HARMONY
FUTURE
USE
J7
J8
J9
J10
J5
J4
J11
W1 W2 G Y2 Y1 C R DH H L O DS
W3
FACTORY
JUMPER
FUSE 3 AMP
F1
XFMR
24V
24 VAC
COM
3
6
9
1
4
7
XFM LINE
7−SEGMENT
LED DISPLAY
DEHUMIDIFICATION−
HARMONY LINK
(JUMPERS R to DS)
HEAT PUMP LINK
(JUMPERS R to O)
2−STAGE
COMPRESSOR LINK
(JUMPERS Y1 to Y2)
ON−BOARD LINK
OPTION SELECTION
1
CBX40UHV JUMPER & LINK GUIDE
−CUT ON−BOARD LINK (SOLDER TRACE)
COMPLETELY
THROUGH BOTH LAYERS ON THE CONTROL BOARD
1
COOLING MODE
BLOWER RAMPING
DELAY
PROFILE #3
OFF−82%−100%−OFF
CLG
HP
DELAY
PROFILE #2
OFF−100%−100%−OFF
OFF−30sOFF−100%−100% OFF
DELAY
PROFILE #1
OFF−100%−OFF
DELAY
PROFILE #4
OFF−50%−82%−
100%−50%−OFF
*
(COOLING MODE UNLESS NOTED)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
R−DS
DEHUM
or
NO HARMONY ZONING
OR NO
COMFORTSENSE 7000
W/ DS CONNECTION
DO NOT CUT
HARMONY ZONING
OR
C0MFORTSENSE 7000
W/ DS CONNECTION
CUT LINK
HARMONY
R−DS
DEHUM
or
HARMONY
1
A/C UNIT
HEAT PUMP UNIT
R−0
HEAT
PUMP
R−0
HEAT
PUMP
1
DO NOT CUT
CUT LINK
2 STAGE
COMPR
1−STG COMPRESSOR
2−STG COMPRESSOR
Y1−Y2
1
DO NOT CUT
CUT LINK
*
*
*
2 STAGE
COMPR
Y1−Y2
*
HUMIDIFICATION MODE
SMART MODE
− ”H” ENABLED WHEN
HEAT ACTIVE
(HP or ELECT. HT)
AUTO MODE
− ”H” ENABLED WHEN
BLOWER ACTIVE
& NO CLG
OR DEHUM
HUMIDIFICATION MODE
24VAC OUTPUT ON ”H”
FOR HUMIDIFIER OR
ACCESSORY INTERLOCK
SMART
AUTO
SMART
AUTO
FACTORY DEFAULT SETTING
*
COOLING MODE
BLOWER SPEED
HIGH
SPEED
MEDIUM−LOW
SPEED
LOW
SPEED
1
2
3
4
MEDIUM−HIGH
SPEED
*
1
2
3
4
1
2
3
4
1
2
3
4
(COOLING & HP MODE)
STANDARD
HEAT MODE
(STAGED BY TSTAT)
STANDARD HEAT MODE
(DEFAULT)
85
110
115
130
HEATING MODE
BLOWER SPEED
*
(ELECTRIC HT MODE)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
LOW
SPEED
MEDIUM−LOW
SPEED
MEDIUM−HIGH
SPEED
HIGH
SPEED
NORM
+
NORM
+
NORM
+
BLOWER
ADJUST SELECTION
NORMAL
(+ 10%)
SETTING
(−10%)
SETTING
*
*
EVENHEATER
®
MODE
85
DEGREE TARGET
DISCHARGE
TEMPERATURE
100
DEGREE
TARGET
115
DEGREE
TARGET
130
DEGREE
TARGET
85
110
115
130
−ENABLED WITH OPTIONAL
DISCHARGE AIR SENSOR
85
110
115
130
85
110
115
130
85
110
115
130
PUSH
BUTTON
HIGH
SPEED
(100%)
MEDIUM−HIGH
SPEED
(70%)
LOW
SPEED
(28%)
*
MEDIUM−LOW
SPEED
(38%)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
CONTINUOUS FAN
MODE BLOWER SPEED
IMPORTANT: USE CARE WHEN CUTTING LINKS TO
PREVENT DAMAGE TO CONTROL.
Figure 11. CBX40UHV-XXX-230-6-01

Table of Contents

Other manuals for Lennox CBX40UHV Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox CBX40UHV Series and is the answer not in the manual?

Lennox CBX40UHV Series Specifications

General IconGeneral
BrandLennox
ModelCBX40UHV Series
CategoryAir Handlers
LanguageEnglish

Related product manuals