User Response
No action; information only.
816f0a07-0302xxxx : The Processor [ProcessorElementName] is no longer operating in a Degraded
State. (CPU 2)
This message is for the use case when an implementation has detected a Processor is no longer running
in the Degraded state.
May also be shown as 816f0a070302xxxx or 0x816f0a070302xxxx
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - CPU
SNMP Trap ID
42
CIM Information
Prefix: PLAT ID: 0039
User Response
No action; information only.
IMM Events that automatically notify Support
You can configure the IBM Flex System Manager or the CMM to automatically notify Support (also known as
call home) if certain types of errors are encountered. If you have configured this function, see the table for a
list of events that automatically notify Support.
Table 8. Events that automatically notify Support
Event ID
Message String
Automatically
Notify Support
80010202-0701xxxx
Numeric sensor [NumericSensorElementName] going low
(lower critical) has asserted. (Planar 12V)
Yes
80010202-2801xxxx
Numeric sensor [NumericSensorElementName] going low
(lower critical) has asserted. (CMOS Battery)
Yes
80010902-0701xxxx
Numeric sensor [NumericSensorElementName] going
high (upper critical) has asserted. (Planar 12V)
Yes
806f0021-2201xxxx Fault in slot [PhysicalConnectorSystemElementName] on
system [ComputerSystemElementName]. (No Op ROM
Space)
Yes
806f0021-2582xxxx Fault in slot [PhysicalConnectorSystemElementName] on
system [ComputerSystemElementName]. (All PCI Error)
Yes
806f0021-3001xxxx Fault in slot [PhysicalConnectorSystemElementName] on
system [ComputerSystemElementName]. (PCI 1)
Yes
806f0108-0a01xxxx [PowerSupplyElementName] has Failed. (Power Supply 1) Yes
806f0108-0a02xxxx [PowerSupplyElementName] has Failed. (Power Supply 2) Yes