Table 9. DSA Preboot messages (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See
Chapter 4 “Parts listing, Lenovo System x3550 M3 Type 4254 and 7944” on page 403 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only)”, that step must be performed only by a
Trained service technician.
• Go to the IBM support website at
http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Message
number
Compo-
nent Test State
Description
Action
shown in the DSA event log in the Firmware/
VPD section for this component. For more
information, see
“Updating the firmware” on
page 513
.
9. Run the test again.
10. If the failure remains, go to the IBM website
for more troubleshooting information at
http://www.ibm.com/support/entry/portal/
docdisplay?lndocid=SERV-CALL
.
089-901-
xxx
CPU CPU
Stress
Test
Failed Test failure.
1. Turn off and restart the system if necessary
to recover from a hung state.
2. Make sure that the DSA code is at the latest
level. For the latest level of DSA code, go to
http://www.ibm.com/support/entry/portal/
docdisplay?lndocid=SERV-DSA
.
3. Run the test again.
4. Make sure that the system firmware is at the
latest level. The installed firmware level is
shown in the DSA event log in the Firmware/
VPD section for this component. For more
information, see
“Updating the firmware” on
page 513
.
5. Run the test again.
6. Turn off and restart the system if necessary
to recover from a hung state.
7. Run the test again.
8. If the failure remains, go to the IBM website
for more troubleshooting information at
http://www.ibm.com/support/entry/portal/
docdisplay?lndocid=SERV-CALL
.
322 System x3550 M3Problem Determination and Service Guide