Table 9. DSA Preboot messages (continued)
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
See
Chapter 4 Parts listing, Lenovo System x3550 M3 Type 4254 and 7944” on page 403 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
If an action step is preceded by “(Trained service technician only)”, that step must be performed only by a
Trained service technician.
Go to the IBM support website at
http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Message
number
Compo-
nent Test State
Description
Action
201-809-
xxx
Memory Memory
Test
Abor-
ted
Test
canceled
program
error:
operation
running fast
scrub.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the DSA code is at the latest
level. For the latest level of DSA code, go to
http://www.ibm.com/support/entry/portal/
docdisplay?lndocid=SERV-DSA
.
4. Make sure that the server firmware is at the
latest level. The installed firmware level is
shown in the DSA event log in the Firmware/
VPD section for this component. For more
information, see
“Updating the firmware” on
page 513
.
5. Run the test again.
6. If the failure remains, go to the IBM website
for more troubleshooting information at
http://www.ibm.com/support/entry/portal/
docdisplay?lndocid=SERV-CALL
.
201-810-
xxx
Memory Memory
Test
Abor-
ted
Test
stopped:
unknown
error code
xxx received
in
COMMO-
NEXIT
procedure.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the DSA code is at the latest
level. For the latest level of DSA code, go to
http://www.ibm.com/support/entry/portal/
docdisplay?lndocid=SERV-DSA
.
4. Make sure that the server firmware is at the
latest level. The installed firmware level is
shown in the DSA event log in the Firmware/
VPD section for this component. For more
information, see
“Updating the firmware” on
page 513
.
5. Run the test again.
6. If the failure remains, go to the IBM website
for more troubleshooting information at
http://www.ibm.com/support/entry/portal/
docdisplay?lndocid=SERV-CALL
.
Chapter 3. Diagnostics 347

Table of Contents