Install a simple-swap drive
Use this information install a simple-swap drive.
“Read the
installation
Guidelines” on
page 59
“Power off
the server
for this task”
on page 12
“ATTENTION:
Static Sensitive Device
Ground package before opening”
on page 60
The following notes describe the type of drives that your server supports and other information that you must
consider when you install a drive.
• For a complete list of supported optional devices for the server, see:
http://www.lenovo.com/us/en/serverproven/
• The drive bays are numbered to indicate the installation order (starting from number “0”). Follow the
installation order when you install a drive. See “Front view” on page 13.
• You can mix drives of different types, different sizes, and different capacities in one system, but not in one
RAID array. The following order is recommended when installing the drives:
– Drive type priority: SSD, SATA HDD
– Drive capacity priority: the lowest capacity first
• The drives in a single RAID array must be the same type, same size, and same capacity.
Before installing a simple-swap drive:
1. If the drive bay has a drive filler installed, remove it. Keep the drive filler in a safe place for future use.
Figure 66. 3.5-inch drive filler removal
2. Touch the static-protective package that contains the new simple-drive to any unpainted surface on the
outside of the server. Then, take the new simple-swap drive out of the package and place it on a static-
protective surface.
Chapter 3. Hardware replacement procedures 93