Loading...
The drive bays are numbered to indicate the installation order (starting from number “0”). Follow the
installation order when you install a drive. See “Front view” on page 13.
You can mix drives of different types, different sizes, and different capacities in one system, but not in one
RAID array. The following order is recommended when installing the drives:
Drive type priority: NVMe SSD, SAS SSD, SATA SSD, SAS HDD, SATA HDD
Drive size priority: 2.5 inch, 3.5 inch
Drive capacity priority: the lowest capacity first
The drives in a single RAID array must be the same type, same size, and same capacity.
Before installing a hot-swap drive:
1. If the drive bay has a drive filler installed, remove it. Keep the drive filler in a safe place for future use.
Figure 70. Drive filler removal
2. Touch the static-protective package that contains the new hot-swap drive to any unpainted surface on
the outside of the server. Then, take the new hot-swap drive out of the package and place it on a static-
protective surface.
To install a hot-swap drive, complete the following steps:
Watch the procedure. A video of the installation process is available:
Youtube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-Acsjj4tU79GzKnWG316BYn
Youku: http://list.youku.com/albumlist/show/id_50483452
Chapter 3. Hardware replacement procedures 97