EDS84AYCER EN 2.0 - 11/2010 L 81
E84AYCER communication manual (PROFINET)
Parameter reference
Parameters of the communication module
C13850
C13851
C13852
Parameter | Name:
C13850 | All words to master
Data type: UNSIGNED_16
Index: 10725
d
= 29E5
h
Display of the process data words which are transmitted from the controller to the IO controller.
In the subcodes 1 to 16, all process data words to the IO controller are displayed. However, only the configured
process data words are valid.
Display range (min. value | unit | max. value)
0 65535
Subcodes Information
C13850/1
...
C13850/16
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13851 | All words from master
Data type: UNSIGNED_16
Index: 10724
d
= 29E4
h
Display of the process data words which are transmitted from the IO controller to the controller.
In the subcodes 1 to 16, all process data words from the IO controller are displayed. However, only the configured
process data words are valid.
Display range (min. value | unit | max. value)
0 65535
Subcodes Information
C13851/1
...
C13851/16
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13852 | All words to standard device
Data type: UNSIGNED_16
Index: 10723
d
= 29E3
h
Display of the process data words 1 ... 16, which are transmitted from the IO controller to the controller.
Display range (min. value | unit | max. value)
0 65535
Subcodes Information
C13852/1
...
C13852/16
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT