EasyManua.ls Logo

Lenze 8400 - Diagnostic Data

Lenze 8400
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EDS84AYCER EN 2.0 - 11/2010 L 71
E84AYCER communication manual (PROFINET)
Diagnostics
Diagnostic data
11.3 Diagnostic data
The IO device sends an alarm message to the IO controller to signalise the diagnostic
data below.
Code C13887
serves to inhibit the transmission of alarm messages to the IO controller.
By this, errors of a specific type can be systematically suppressed.
Errors and warnings in the Inverter Drive 8400 and the plugged-in module are sent to
the IO controller as extended diagnostic messages.
The diagnostic data can be displayed using the hexadecimal representation of the
Siemens S7 engineering tool.
Bytes Meaning Value [hex]
1 ... 6 Diagnostic block header 0x0010 001C 0100
7 ... 8 Alarm type 0x0001 (Diagnosis)
9 ... 12 API (Application Programming Interface) 0x0000 0000
13, 14 Slot number 0x0001 / 0x0002
15, 16 Subslot number 0x0001
17 ... 20 Module ID ID according to module
21 ... 24 Submodule number ID according to module
25, 26 Alarm specification 0xB000
27, 28 User structure ID 0x0001
29 ... 32 Error code