EDS84AYCER EN 2.0 - 11/2010 L 83
E84AYCER communication manual (PROFINET)
Parameter reference
Parameters of the communication module
C13862
C13864
Parameter | Name:
C13862 | Bus counter
Data type: UNSIGNED_32
Index: 10713
d
= 29D9
h
Display of data cycles per second (irrespective of data changes)
Display range (min. value | unit | max. value)
0 4294967295
Subcodes Information
C13862/1 Data cycles per second
C13862/2 Read cycles per second
C13862/3 Write cycles per second
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13864 | Active station name
Data type: VISIBLE_STRING
Index: 10711
d
= 29D7
h
Displays the active station name used by the controller.
It may differ from the contents of code C13899
, depending on whether the station name has been changed via the
fieldbus or via C13899
.
Setting the station name
( 36)
Subcodes Information
C13864/1 1st ... 30th character
C13864/2 31st ... 60th character
C13864/3 61st ... 90th character
C13864/4 91st ... 120th character
C13864/5 121st ... 150th character
C13864/6 151st ... 180th character
C13864/7 181st ... 210th character
C13864/8 211th ... 240th character
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT