EDS84AYCER EN 2.0 - 11/2010 L 87
E84AYCER communication manual (PROFINET)
Parameter reference
Parameters of the communication module
C13900
C13901
C13902
C13910
C13911
C13912
Parameter | Name:
C13900 | Firmware product type
Data type: VISIBLE_STRING
Index: 10675
d
= 29B3
h
The code contains a string with a length of 8 bytes. The identification code "E84DFYER" is displayed.
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13901 | Firmware compilation date
Data type: VISIBLE_STRING
Index: 10674
d
= 29B2
h
The code contains a string with a length of 20 bytes. The software creation date ("MMM DD YYYY") and time
("hh:mm:ss") are displayed (e.g. "Mar 21 2005 12:31:21").
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13902 | Firmware version
Data type: VISIBLE_STRING
Index: 10673
d
= 29B1
h
The code contains a string with a length of 11 bytes. The identification code is displayed (e.g. "01.00.00.00").
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13910 | I&M1 System designation
Data type: VISIBLE_STRING
Index: 10665
d
= 29A9
h
Input/output of the I&M1 plant identification code
The Lenze setting shows an empty string.
; Read access ; Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13911 | I&M1 Installation site
Data type: VISIBLE_STRING
Index: 10664
d
= 29A8
h
Input/output of the I&M1 location identification code
The Lenze setting shows an empty string.
; Read access ; Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13912 | I&M2 Installation date
Data type: VISIBLE_STRING
Index: 10663
d
= 29A7
h
Input/output of the I&M2 date of installation
The Lenze setting shows an empty string.
; Read access ; Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT