Commissioning
5-8
BA9300POS EN 2.3
5.6.3 Enter machine parameters
1
2
3
4
5
6
7
Fig. 5-5 ”Base settings” dialog box
Field
Command Function
1 Click on field ”Gearbox numerator” Enter denominator for the
gearbox ratio.
i
n
motor
n
gearbox output
2 Click on field ”Gearbox denominator” Enter numerator for the
gearbox ratio.
The value results from the number of units (e. g. mm)
being moved forward during one rotation at the gearbox
output side.
3 Click on field ”Feed constant” Enter feed of the spindle.
4 Click on field ”Speed (n-max)” Enter upper speed limit of the motor
5 Click on field ”speed (v-max)” Enter fastest positioning speed of the machine
6 Click on field ”Acceleration (a-max)” Maximum permissible acceleration (with interference or during approach to position
limit switches a-max cannot be activated).
7 Click on field ”QSP ramp” Time from release of fault or approach to a position limit switch to machine
standstill.