Commissioning
5-30
BA9300POS EN 2.3
5.11.2.1 Password protection
Code LCD
Possible settings
IMPORTANT
Lenze Selection
C0094 Password 0 0 {1} 9999 Password
Parameter access protection for the operating
module. When the password is activated, only
the codes of the user menus can be accessed.
For further selection possibilities see C0096
[C0096]
1
2
AIF protect.
CAN protect.
0
0
0 Nopasswordprotection
1 Read protection
2 Write protection
3 Read/Write protection
Extended password protection for bus systems
with activated password (C0094).
All codes in the user menu can be accessed.
You can restrict the code access via the operating module using the password protection in C0094.
Reading C0094 using the operating module:
C0094 = 0: password protection is not activated.
C0094 = 9999: password protection is activated.
Activate password protection:
Enter four-digit number in C0094.
–ConfirmusingSH+PRG.
Deactivate password protection:
Enter four-digit number again.
All other inputs are refused.
Effect
Working with the operating module:
The codes listed in the USER menu can still be read and changed.
All other codes are no longer displayed.
Working with the fieldbus:
It is possible to extend the protection for codes via the fieldbus under C0096/1 (AIF) and
C0096/2 (CAN).