Questions and Answers

  • J
    john52Aug 10, 2025
    What does 'HI TEMP' mean on my Lenze AC Tech M3103S Controller?
    • D
      David JohnsonAug 10, 2025
      The 'HI TEMP' error on your Lenze Controller suggests that the ambient temperature is too high or there is a fan failure, if a fan is installed.
  • R
    rebeccahartAug 16, 2025
    Why does my Lenze AC Tech M3103S show 'HI VOLTS'?
    • S
      smillsAug 16, 2025
      The 'HI VOLTS' error on your Lenze Controller is triggered by high line voltage, an overhauling load, or a deceleration rate that is set too fast.
  • L
    Lori HamiltonAug 23, 2025
    What does 'PWR SAG' mean on Lenze AC Tech M3103S and how to fix it?
    • P
      Philip BrooksAug 23, 2025
      The 'PWR SAG' error on your Lenze Controller can appear due to erratic AC line or if a new control board has been installed that is different from the previous version. To fix this, perform a factory reset using Parameter 65-PROGRAM. This will update the software and allow the fault to be reset.
  • C
    Carol WagnerAug 29, 2025
    Why does my Lenze Controller display 'LO VOLTS'?
    • B
      Bridget PayneAug 29, 2025
      The 'LO VOLTS' error on your Lenze Controller is caused by low line voltage.
  • B
    bishopbarbaraSep 4, 2025
    What does 'PWR TRAN' mean on my Lenze AC Tech M3103S Controller?
    • M
      Melanie LunaSep 4, 2025
      The 'PWR TRAN' error on your Lenze Controller indicates that the AC line dipped or sagged.