M301L 41
PARAMETER MENU
PARAM.
NUMBER
PARAMETER
NAME
RANGE OF
ADJUSTMENT
FACTORY
DEFAULT
28 AUTO/MAN
A / M LOC
AUTO
MANUAL
A / M SPD
A / M LOC
30 CONTROL
LOCAL
REMOTE
SERIAL
KEYPAD
TB STRIP
KEYPAD 2
LOCAL
31 UNITS
sp: HERTZ, RPM, % HZ,
speed: HERTZ
/SEC, /MIN, /HR, GPH, NONE
pid: %, PSI, FPM, CFM, GPM, IN,
FT, /SEC, /MIN, /HR, F, C, MPM,
GPH
32 HZ MULT 0.10 - 650.0 1.00
33 UNITS DP
XXXXX
XXX.X
XX.XX
X.XXX
.XXXX
XXXXX
34 LOAD MLT 95 - 139 % 100%
35 CONTRAST
LOW
MED
HIGH
MED
36 SLEEP TH 0.00 - 360.0 Hz 0.00 Hz
37 SLEEP DL 0.0 - 300 SEC 30.0 SEC
38 SLEEP BW FB @ MIN - FB @ MAX 0%
39 TB5 MIN 0.00 - 360.0 Hz 0.00 Hz
40 TB5 MAX 0.00 - 360.0 Hz 60.00 Hz
41 AIN FLTR 0.01 - 10.0 SEC 0.02 SEC
42 TB10A OUT
NONE
0-10V
2-10V
NONE
43 @TB10A 0.00 - 360.0 Hz 60.00 Hz
44 TB10B OUT
NONE
0-10V
2-10V
NONE
45 @TB10B 10 - 200 % 125 %
47 TB13A
NONE, 0-10VDC, 4-20MA,
NONESPEED#1, LOC SEL,
DEC FREQ