Appendix
Code table
14−19
L
EDB82MV752 EN 5.2
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0101
(A)
Acceleration times
− main setpoint
0.00 {0.02 s} 1300.00 7−24
1 C0012 5.00
Binary coding of the digital signal sources
assigned to C0410/27 and C0410/28
determine the active time pair
2 T
ir
1 2.50
3 T
ir
2 0.50
4 T
ir
3 10.00
C0103
(A)
Deceleration times
− main setpoint
0.00 {0.02 s} 1300.00 C0410/27 C0410/28
LOW LOW
HIGH LOW
LOW HIGH
HIGH HIGH
Active
C0012; C0013
T
ir
1; T
if
1
T
ir
2; T
if
2
T
ir
3; T
if
3
1 C0013 5.00
2 T
if
1 2.50
3 T
if
2 0.50
4 T
if
3 10.00
C0105 Deceleration time
quick stop (QSP)
5.00 0.00 {0.02 s} 1300.00 Quick stop (QSP) decelerates the drive
to standstill according to the ramp set
under C0105.
If the output frequency falls below the
threshold C0019, the DC−injection brake
(DCB) will be activated.
The S−shaped ramp (C0182) has also an
effect on quick stop!
– Reduce the time setting under C0105
to reach the desired deceleration
time for quick stop.
– The S−shaped ramp for the quick stop
can be switched off under C0311 (as
of software 3.1).
7−27
C0106 Hold time for
automatic
DC−injection brake
(Auto DCB)
0.50 0.00
= auto DCB not active
{0.01 s} 999.00
=
Hold time, if DC−injection brake is activated
because the value falls below the setting
under C0019.
7−30
C0107 Hold time DC
injection brake
(DCB)
999.00 1.00 {0.01 s} 999.00
=
Hold time, if DC−injection brakes are
activated via an external terminal or control
word.
7−30
C0108* Gain analog output
X3/62
(AOUT1−GAIN)
128 0 {1} 255 Standard I/O: C0108 and C0420 are the
same
Application I/O: C0108 and C0420/1 are the
same
7−59
C0109* Offset analog
output X3/62
(AOUT1−OFFSET)
0.00 −10.00 {0.01 V} 10.00 Standard I/O: C0109 and C0422 are the
same
Application I/O: C0109 and C0422/1 are the
same
7−59