EasyManua.ls Logo

Lenze E82MV152_4B

Lenze E82MV152_4B
270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table of keywords
abc
15−2
L
EDB82MV752 EN 5.2
400 V/500 V, 3−10
operation with rated power
230 V, 3−5
400 V/500 V, 3−8
Cable specification, 4−6
Calibration, Application datum, 7−86
calling a password−protected function, 6−7
CAN bus identifier, 14−32
CAN bus node address, 14−31
Changeover, Setpoints, 7−47
Changing and saving parameters, with E82ZBC keypad, 5−3
Character format, 6−9
Check, before commissioning, 5−1
Chopper frequency reduction, 7−15
Code, 6−1
Code bank, 6−14
Code table, LECOM−A (RS232) communication module, 6−12
Codetabelle, Erläuterungen zur, 14−10
Codetabelle Antriebsregler, 14−10
Commissioning, 5−1
check before, 5−1
V/f characteristic control, 5−6
without function module, 5−6 , 5−8 , 5−10 , 5−12
Vector control, 5−10
Vector control optimisation, 5−14
Communication error, Reaction to, 14−21
Communication monitoring, LECOM−A (RS485) function
module, 6−14
Communication times, LECOM−A (RS232) communication
times, 6−10
Compensation equipment, interaction with, 4−5
Configuration
Acceleration times and deceleration times, 7−24
Actual value selection, 7−32
Analog input signals, 7−57
Analog output signals, 7−59
Analog outputs, 7−59
Analog process data output words, 7−64
Change of direction of rotation, 7−28
Communication monitoring, 14−21
Controller inhibit (DCTRL1−CINH), 7−20
Current limits, 7−23
Current−limit controller, 7−56
DC−injection brake (DCB), 7−30
Digital input signals, 7−68
Digital output signals, 7−73
Digital outputs, 7−73
Display functions, 7−86
Function library, 7−1
Manual / remote operation, 7−47
Maximum field frequency, 7−21
Minimum field frequency, 7−21
Monitoring functions
external faults, 7−85
Motor temperature, 7−82
Motor data detection, 7−48
Oscillation damping, 7−16
Parameter set changeover, 7−94
Process data output words, 7−79
Quick stop (QSP), 7−27
Relay output, 7−73
Setpoint selection, 7−32
Setpoint source selection, 7−32
Slip compensation, 7−13
Speed limit values, 7−21
Start conditions/flying−restart circuit, 7−18
switching frequency of inverter, 7−14
table of attributes, 14−51
Thermal motor monitoring, 7−82
TRIP reset, 7−85
TRIP set, 7−85
V/f rated frequency, 7−5
Vmin boost, 7−7
Conformity, 3−1
Control characteristics, Process controller, 7−50
Control connections
terminal assignment − application I/O, 4−12
terminal assignment − bus function modules, 4−16
terminal assignment − standard I/O, 4−9
Control mode, Selection, 5−4
Control word, 14−22
Controlled deceleration after mains failure, 7−19
Controller
Application as directed, 1−2
Labelling, 1−2
Controller inhibit, Drive performance, 7−18 , 7−20
Current derating
operation with increased rated power, 400 V/500 V, 3−10
operation with rated power, 400 V/500 V, 3−8
Current limits, 7−23
Current−limit controller, 7−56
Cyclic mains switching, 5−6 , 5−10
D
DC−bus connection, 10−1
Several drives, 10−1
DC−bus operation, 3−1
DC−injection brake, 7−30
Dead band
setting with auto DCB, 7−31
With analog setpoint selection, 7−35
Debouncing
Digital output signal "Torque threshold reached", 14−29

Table of Contents

Related product manuals