8400 StateLine C | Operating instructions
Connection/wiring of the controller
12 L from Firmware V06.00 - DMS 1.1 EN - 11/2011
4 Connection/wiring of the controller
[4-1] Wiring of the power and motor terminals of 230V devices (on the left) and 400V devices (on the right)
[4-2] Wiring of the control terminals / preconfigured assignment (Lenze setting)
J>
PE
Rb1 Rb2
U
V W
X105
T1 T2
X106
"
M
3~
PTC
"
R
b
"
M
3~
"
"
Rb1 Rb2
+
+
+
+
E84AVSCxxxx ...2
1/N/PE AC 230 V
PE
L1
N
PE
F1
K
Z
L1
N
X100
F2
K
K
O
I
R
b
J
+
J>
PE
Rb1 Rb2
U
V W
X105
T1 T2
X106
"
M
3~
PTC
"
R
b
"
M
3~
"
"
Rb1 Rb2
+
+
+
+
E84AVSCxxxx ...4
PE
3/PE AC 400 V/500 V
L1
L2
L3
N
PE
F1…F3
K
Z
L1
+UG
L2
L3
-UG
X100
F4
K
K
O
I
R
b
J
+
X3 - Analog terminals
A1U Main speed setpoint
10 V 100 % reference speed 1500 rpm
(applies to 4-pole asynchronous motors)
O1U Actual speed value
10 V 100 % reference speed 1500 rpm
X4 - Digital terminals
24E External supply - control electronics (optional)
RFR Controller enable / Reset of error message
DI1 Fixed speed setpoint 1 (40 % of the reference speed)
DI2 Fixed speed setpoint 2 (60 % of the reference speed)
DI3 Manual DC-injection braking
DI4 Change of direction of rotation
DO1 Status "Drive is ready"
X101 - relay output
COM/NO Status "Error is pending"
&20
1&
12
$5
$8
$,
*$
28
(
,
5)5
',
',
',
',
'2
*,2
*1'$
9P$
*1',2
;
;
;
9
9
N
9'&
($96&[[[[[

Table of Contents