EasyManua.ls Logo

Lenze E84AVSC - Speed Limit Values

Lenze E84AVSC
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8400 StateLine C | Operating instructions
Adapting the application individually
Activating additional functions in the signal flow
60 L from Firmware V06.00 - DMS 1.1 EN - 11/2011
8.2.1 Speed limit values
C00635
C00636
C02611/x
L_NSet_1: nMaxLimit
Maximum speed setpoint for speed setpoint limitation
Setting range (min. value | unit | max. value) Lenze setting
-199.99 % 199.99 199.99 %
L_NSet_1: nMinLimit
Minimum speed setpoint for speed setpoint limitation
Setting range (min. value | unit | max. value) Lenze setting
-199.99 % 199.99 -199.99 %
MCK: Limitations
Speed setpoint limits for the determination of limited validity ranges
Note:
Traversing with setpoints through resulting blocking zones is executed with the ramp set in C02610/2
:
setpoint range synchronisation range
Setting range (min. value | unit | max. value)
0.00 % 199.99
Subcodes Lenze setting Info
C02611/1 199.99 % MCK: Pos. max. speed
Upper limit of the speed setpoint limitation in
positive direction of rotation.
C02611/2 0.00 % MCK: Pos. min. speed
Lower limit of the speed setpoint limitation in
positive direction of rotation.
C02611/3 0.00 % MCK: Neg. min. speed
Lower limit of the speed setpoint limitation in
negative direction of rotation.
C02611/4 199.99 % MCK: Neg. max. speed
Upper limit of the speed setpoint limitation in
negative direction of rotation.
Sync
Sync
v
t
C02611/1
C02611/2
C02611/3
C02611/4
C02610/2
0
1
0
nSpeedSetValue_a nSpeedSetValue_a_
C02610/2

Table of Contents

Related product manuals