8400 StateLine C | Operating instructions
Diagnostics & troubleshooting
Monitoring
48 L from Firmware V06.00 - DMS 1.1 EN - 11/2011
7.4 Monitoring
The controller is provided with various monitoring functions which protect the drive
against impermissible operating conditions.
If a monitoring function responds,
an entry will be made into the logbook
of the controller,
the response (TroubleQSP, Warning, Fault, etc.) set for this monitoring function will be
triggered,
the status of the internal device control changes according to the selected response,
controller inhibit is set, and the "DRIVE ERROR" LED on the front of the controller goes
on:
Response
Entry in the
logbook
Display in
C00168
Pulse inhibit Controller
inhibit
Acknowledgem
ent required
LED "DRV-ERR"
None OFF
Fault ;;;;;
Trouble ;;;;
(after 0.5 s)
TroubleQSP ;; ;
WarningLocked ;; ;
Warning ;;
Information ; OFF
System error ;;;;
Mains switching