EasyManua.ls Logo

Lenze E84DGFCA Series - 4.3 Communication time

Lenze E84DGFCA Series
75 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 5.0 - 02/2019 19
Technical data
Communication time
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.3 Communication time
The communication time is the time between the start of a request and the arrival of the
corresponding response.
The communication times in an AS-i network depend on the ...
processing time in the inverter;
frame runtime (baud rate / frame length);
nesting depth of the network.
Processing time in the inverter
There are no interdependencies between parameter data and process data.
Data Processing time
Process data Approx. 2 ms
+ 0 ... 1 ms
+ 1 ... x ms
Update cycle
Processing time in the module
Runtime of the application task of the technology
application used (tolerance)
Parameter data Approx. 30 ms + a tolerance of 20 ms (typically)
For some codes, the processing time may be longer (see software manual/
»Engineer« online help "Inverter Drives 8400 motec").

Table of Contents

Related product manuals